Anaheim Automation MBC10P31 Guía de usuario

Busca en linea o descarga Guía de usuario para Generadores De Poder Anaheim Automation MBC10P31. Anaheim Automation MBC10P31 User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - MBC10P31 Series

August 2012L010184MBC10P31 SeriesProgrammable Pulse GeneratorUser’s Guide910 East Orangefair Lane, Anaheim, CA 92801e-mail: [email protected]

Pagina 2 - MBC10P31 Features

August 2012L0101848 Lead MotorsSeries Connection: When confi guring the motor windings in series, use the per phase (or uni-polar) current rating to de

Pagina 3

August 2012L010184FunctionsHard Limit Switches: When a hard limit switch is encountered, the pulses will stop. Hard limits are intended as an emergen

Pagina 4 - Inputs and Outputs

August 2012L010184SMPG-SMSI SoftwareThe SMPG-SMSI software is a handy utility that supports Anaheim Automation’s programmable pulse generators and sim

Pagina 5 - Connector Descriptions

August 2012L010184File MenuSetup MenuToolbarExit Exit the SMPG10WIN SoftwareConnect Establish communications with the controller.Disconnect Discontinu

Pagina 6 - Specifi cations

August 2012L010184Program WindowMotion Profi le Select motion profi les 1 or 2.Send Accel/Decel Send the acceleration & deceleration parameter to th

Pagina 7 - Wiring Diagrams

August 2012L010184Direct Talk ModeDirect mode is used to directly control the motion for real time movements through serial com-munication. The pulse

Pagina 8 - Reducing Output Current

August 2012L010184$ - Versions Number RegisterFormat: $Description: This command request the pulse generator to return the version number.! - Error

Pagina 9 - 4 Lead Motors

August 2012L010184C - Current Reduce OptionFormat: C# - where # is 0 or 1Description: This command enables the driver to reduce current after pulse

Pagina 10 - Circuit Protection

August 2012L010184S - Stop SoftFormat: SDescription: This command will cause the pulse generator to ramp down to base speed and stop. It can only

Pagina 11 - Functions

August 2012L010184Visual Basic Direct Mode Programming ExamplesExample 1: This Example is for Axis=0, and Profi le=1DimConst DefaultTimeout As Single =

Pagina 12 - Getting Started

August 2012L010184General DescriptionThe MBC10P31 is a low-cost single axis step motor driver integrated with a programmable pulse genera-tor. The MB

Pagina 13 - File Menu

August 2012L010184TroubleshootingProblem:Can not establish communications with the unit.Possible Solutions: 1. Make sure the indexer has power. Is t

Pagina 14 - Program Window

August 2012L010184ASCII Symbol Hex ValueASCII SymbolHex ValueCarriage Return 0D C 43030D44131G47232H48333M4D434S53535V56636!217 37$24838+2B939-2DA41_5

Pagina 15 - August 2012L010184

August 2012L010184ANAHEIM AUTOMATIONCOPYRIGHT Copyright 2007 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced

Pagina 16 - B - Base Speed

August 2012L010184Operation with Ramp Down OptionA. Run is activated; Starts at base speed and immediately ramps up to max speed.B. Run is still act

Pagina 17 - M - Max Speed

August 2012L010184LEDsWhen powered and operated properly, the status LED will be green. When an error occurs, the LED will change to RED and an error

Pagina 18 - V - Verify

August 2012L010184Connector P2:Pin # Description1 Power Supply Ground (0VDC)2 Power Supply Input (20VDC - 80VDC)3 Motor Phase 1 (A)4 Motor Phase 3 (/A

Pagina 19

August 2012L010184Ordering InformationSpecifi cationsPart Number DescriptionMBC10P31 10.0A Microstep Driver with integrated programmable Pulse Generato

Pagina 20 - Troubleshooting

August 2012L010184DimensionsWiring Diagrams

Pagina 21 - Error Codes

August 2012L010184Setting the Output CurrentThe output current on the MBC10P31 is set by the on-board potentiometer. This current adjust potentiomete

Pagina 22 - ANAHEIM AUTOMATION

August 2012L010184Determine Output CurrentThe output current used for motor when microstepping is determined differently from that of a full/half step

Comentarios a estos manuales