Anaheim Automation DPG10003-01 Guía de usuario Pagina 1

Busca en linea o descarga Guía de usuario para Las Llaves De Impacto De Energía Anaheim Automation DPG10003-01. Anaheim Automation DPG10003-01 User`s guide [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
December 2004
DPG10002-01, DPG10003-01, DPG10004-01
Microstep Driver Pack
User’s Guide
#L010167
910 East Orangefair Lane, Anaheim, CA 92801
(714) 992-6990 fax: (714) 992-0471
website: www.anaheimautomation.com
ANAHEIM AUTOMATION
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Microstep Driver Pack

December 2004DPG10002-01, DPG10003-01, DPG10004-01Microstep Driver PackUser’s Guide#L010167910 East Orangefair Lane, Anaheim, CA 92801e-mail: info@ana

Pagina 2 - Pin Descriptions

User’s Guide # L010167Dimension DrawingsDPG10002-01, DPG10003-01 and DPG10004-01 Micostep Driver Pack

Pagina 3 - Power Supply Requirements

December 2004COPYRIGHTCopyright 2001 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcrib

Pagina 4 - Electrical Specifications

User’s Guide # L010167ANAHEIM AUTOMATIONTorque Speed Curves

Pagina 5 - Motor Selection

User’s Guide # L010167DPG10002-01, DPG10003-01, DPG10004-01 Microstep Driver Pack Features• Integrated MBC10641, Power Supply, and Cooling Fan• 90-265

Pagina 6 - Setting the Output Current

December 2004#niP noitpircseD1:)+(edonAtupnIkcolCpetS enorotomehtsecnavdatupnidetalosisihtnoegdegniogevitisopA.1hctiwSfostupnItceleSpetsorciMehtnotned

Pagina 7 - Determining Output Current

User’s Guide # L010167Absolute Maximum RatingsInput Voltage: 90-265 VACOutput Current: 10.0 AMPS PEAKMax Plate Temperature: 70° CStorage Temperature:

Pagina 8 - Step Motor Configurations

December 2004Optically Isolated InputsThe following inputs to the MBC10641 are Optically Isolated.To enable an input, apply a DC voltage source of +5V

Pagina 9 - Connecting the Step Motor

User’s Guide # L010167Microstep Selection (SW1 Settings)Switches 2, 3 and 4, of the DIP switch select the number of microsteps per step. Table 7 shows

Pagina 10 - Dimension Drawings

December 2004Step Motor Selection GuideAnaheim Automation offers motor cable, making hook-ups quick and easy!Contact the factory or visit our website

Pagina 11 - December 2004

User’s Guide # L0101674 Lead MotorsMultiply the specified series motor current by 1.4 to determine the current adjustment potentiometervalue. Four Lea

Pagina 12 - ANAHEIM AUTOMATION

December 20048 Lead MotorsSeries Connection: When configuring the motor windings in series, use the per Phase (or unipolar)current rating to determine