Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER MBC10SI1 Guía de usuario

Busca en linea o descarga Guía de usuario para No Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER MBC10SI1. Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER MBC10SI1 User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - MBC10SI1

August 2012L0101851MBC10SI1Programmable Simple Indexer/DriverUser’s Guide910 East Orangefair Lane, Anaheim, CA 92801e-mail: [email protected]

Pagina 2 - MBC10SI1 Features

August 2012L010185108 Lead MotorsSeries Connection: When confi guring the motor windings in series, use the per phase (or uni-polar) current rating to

Pagina 3 - Normal Operation

August 2012L01018511FunctionsHard Limit Switches: When a hard limit switch is encountered, the pulses will stop. Hard limits are in-tended as an emer

Pagina 4 - Inputs and Outputs

August 2012L01018512SMPG-SMSI SoftwareThe SMPG-SMSI software is a handy utility that supports Anaheim Automation’s programmable pulse generators and s

Pagina 5 - Connector Descriptions

August 2012L01018513File MenuSetup MenuToolbarExit Exit the SMPG10WIN SoftwareConnect Establish communications with the controller.Disconnect Disconti

Pagina 6 - Specifi cations

August 2012L01018514Program WindowMotion Profi le Select motion profi les 1, or 2.Send Accel/Decel Send the acceleration & deceleration parameter to

Pagina 7 - Wiring Diagrams

August 2012L01018515Direct Talk ModeDirect mode is used to directly control the motion for real time movements through serial com-munication. The ind

Pagina 8 - Reducing Output Current

August 2012L01018516$ - Version Number RegisterFormat: $Description: This command request the pulse generator to return the version number.! - Erro

Pagina 9 - 4 Lead Motors

August 2012L01018517C - Current Reduce OptionFormat: C# - where # is 0 or 1Description: This command enables the driver to reduce current after pul

Pagina 10 - Circuit Protection

August 2012L01018518S - Stop SoftFormat: SDescription: This command will cause the indexer to ramp down to base speed and run until the index is co

Pagina 11 - Functions

August 2012L01018519Visual Basic Direct Mode Programming ExamplesExample 1: This Example is for Axis=0, and Profi le=1DimConst DefaultTimeout As Single

Pagina 12 - Getting Started

August 2012L0101852General DescriptionThe MBC10SI1 is a low cost single axis step motor driver integrated with a programmable simple indexer. The MBC

Pagina 13 - File Menu

August 2012L01018520TroubleshootingProblem:Can not establish communications with the unit.Possible Solutions: 1. Make sure the indexer has power. Is

Pagina 14 - Program Window

August 2012L01018521ASCII Symbol Hex ValueASCII SymbolHex ValueCarriage Return 0D C 43030G47131H48232M4D333N4E434R52535S53636V56737!218 38$24939+2BA41

Pagina 15 - August 2012L010185

August 2012L01018522ANAHEIM AUTOMATIONCOPYRIGHT Copyright 2012 by Anaheim Automation. All rights reserved. No part of this publication may be reproduc

Pagina 16 - B - Base Speed

August 2012L0101853Motion Profi les and Running the Indexer: ContinuedNormal OperationA. A Profi le input is activated; Ramps up to max speed.B. No lim

Pagina 17 - N - Index Number

August 2012L0101854LEDsWhen powered and operated properly, the status LED will be green. When a communication or program syntax error occurs, the LED

Pagina 18 - V - Verify

August 2012L0101855Connector DescriptionsConnector P2:Pin # Description1 Power Supply Ground (0VDC)2 Power Supply Input (20VDC - 80VDC)3 Motor Phase 1

Pagina 19

August 2012L0101856Ordering InformationSpecifi cationsPart Number DescriptionMBC10SI1 10.0A Microstep Driver with Integrated Programmable Simple Indexe

Pagina 20 - Troubleshooting

August 2012L0101857DimensionsWiring Diagrams

Pagina 21 - Torque Speed Curves

August 2012L0101858Setting the Output CurrentThe output current on the MBC10SI1 is set by the on-board potentiometer R29 (Refer to Dimen-sions/Jumper

Pagina 22 - ANAHEIM AUTOMATION

August 2012L0101859Determine Output CurrentThe output current used for motor when microstepping is determined differently from that of a full/half ste

Comentarios a estos manuales