Anaheim Automation PROGRAMMABLE SIMPLE INDEXER/DRIVER MBC10SI1 Guía de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
August 2012L010185
3
Motion Pro les and Running the Indexer: Continued
Normal Operation
A. A Pro le input is activated; Ramps up to max speed.
B. No limit is active; Max speed is reached (keeps running at max speed).
C. No Limit is active; Internal counter signals to ramp down to base speed.
D. Internal Counter is complete; Base speed is reached. Pulses stop.
Soft Limit Activated During Index
A. A Pro le input is activated; Ramps up to max speed.
B. No limit is active; Max speed is reached (keeps running at max speed).
C. Soft limit is activated; Ramp down to base speed.
D. Base speed is reached; Continue until counter is complete.
E. Internal Counter is complete; Pulses stop.
Hard Limit Activated During Index
A. A Pro le input is activated; ramps up to max speed.
B. No limit is active; Max speed is reached (keeps running at max speed).
C. Hard limit is activated; Pulses stop (Index did not complete).