January 2013L010197
MBC05641
Bipolar Microstep Driver
Users Guide
910 East Orangefair Lane, Anaheim, CA 92801
(714) 992-6990 fax: (714) 992-0471
website: www.anaheimautomation.com
ANAHEIM AUTOMATION
Vista de pagina 0
1 2 3 4 5 6 ... 44 45

Indice de contenidos

Pagina 1 - Bipolar Microstep Driver

January 2013L010197MBC05641Bipolar Microstep DriverUser’s Guide910 East Orangefair Lane, Anaheim, CA 92801e-mail: [email protected](714) 992-

Pagina 2 - MBC05641 Features

January 2013L010197ANAHEIM AUTOMATIONCOPYRIGHT Copyright 2013 by Anaheim Automation. All rights reserved. No part of this publication may be reproduce

Pagina 3

FEATURESOPTIONAL POWER SUPPLY910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comD

Pagina 4

DIMENSION910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comWIRING

Pagina 5

910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comSPECIFICATIONSTORQUE CURVESPow

Pagina 6 - Step Motor Selection Guide

#L010143 November 2003MBC10641Bipolar Microstep DriverUser’s Guide910 East Orangefair Lane, Anaheim, CA 92801e-mail: [email protected](714) 9

Pagina 7 - Step Motor Confi gurations

#L010143 November 2003MBC10641 Microstep Driver Features• Size 6.500"L x 2.025"W x 5.400"H• Output Current 10.0 Amps Peak• 200 to 12

Pagina 8 - January 2013L010197

#L010143 November 2003#niP noitpircseD1:)+(edonAtupnIkcolCpetS enorotomehtsecnavdatupnidetalosisihtnoegdegniogevitisopA.1hctiwSfostupnItceleSpetsorciM

Pagina 9

#L010143 November 2003Transformer Drawings - Hook UpsFigure 2: Wiring for various line voltages for the AA3621.Absolute Maximum RatingsInput Voltage:

Pagina 10 - ANAHEIM AUTOMATION

#L010143 November 2003Power Connector RequirementsIt is necessary that fully insulated female quick connect connectors be used for QD1, QD2 and QD3.Pa

Pagina 11

#L010143 November 2003Motor SelectionThe MBC10641 is a Bipolar Microstep Driver that is compatible with both Bipolar and Unipolar MotorConfigurations,

Pagina 12 - DIMENSION

January 2013L010197General DescriptionThe MBC05641 Microstep Motor Driver has an output current capability of 0.5 Amps minimum to 5.0 Amps maximum (Pe

Pagina 13 - TORQUE CURVES

#L010143 November 2003Microstep Selection (SW1 Settings)Switches 2, 3 and 4, of the DIP switch select the number of microsteps per step. Table 6 shows

Pagina 14 - MBC10641

#L010143 November 2003When configuring the motor in a series configuration (connected from end to end with the center tapfloating) use the specified p

Pagina 15 - Pin Descriptions

#L010143 November 20034 Lead MotorsMultiply the specified series motor current by 1.4 to determine the current adjustment potentiometervalue. Four Lea

Pagina 16 - Power Supply Requirements

#L010143 November 2003Dimension DrawingFigure 5: MBC10641 dimensionsConnecting the Step MotorPhase 1 and 3 of the Step Motor is connected between pins

Pagina 17 - Electrical Specifications

#L010143 November 2003Torque Speed Curves

Pagina 18 - Hook Up Drawings

#L010143 November 2003ANAHEIM AUTOMATIONTorque Speed CurvesCOPYRIGHTCopyright 2003 by Anaheim Automation. All rights reserved. No part of this publi

Pagina 19 - Motor Selection

FEATURESDIMENSIONS/WIRING DIAGRAMS910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation

Pagina 20 - Setting the Output Current

CONNECTOR TB1 (INPUT)910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comSPECIFICA

Pagina 21 - 6 Lead Motors

January 2013L010133MBC15081Bipolar Microstep DriverUser’s Guide910 East Orangefair Lane, Anaheim, CA 92801e-mail: [email protected](714) 992-

Pagina 22 - 8 Lead Motors

January 2013L010133General DescriptionThe MBC15081 is a 1.5 amps/phase bipolar microstep driver capable of running four, six, and eight lead step moto

Pagina 23 - Connecting the Step Motor

January 2013L010197To enable an input, apply a DC voltage source of +5VDC to +24VDC across the inputs. The Anodes (+) are pins 1, 3 and 5 and the Cat

Pagina 24 - Torque Speed Curves

January 2013L010133Wiring DiagramsInput Pin DescriptionsPin # DescriptionCBL-AA4031 Wire Color1 Direction Brown2 Clock Red3 On/Off Orange4 MS2 Yellow5

Pagina 25

January 2013L010133Step Motor Confi gurationsThe output current on the MBC15081 is set by the onboard potentiometer. This potentiometer determines the

Pagina 26 - MBC158 Microstep Driver

January 2013L010133Step Motor Confi gurationsStep motors can be confi gured as 4, 6 or 8 leads. Each confi guration requires different currents. Refer

Pagina 27

January 2013L010133Connecting to the MBC15081The MBC15081 is designed with cost savings and size as two of the primary design criteria. For this reas

Pagina 28 - MBC15081

January 2013L010133ANAHEIM AUTOMATIONCOPYRIGHT Copyright 2013 by Anaheim Automation. All rights reserved. No part of this publication may be reproduce

Pagina 29 - Dimensions

January 2013L010132MBC25081Bipolar Microstep DriverUser’s Guide910 East Orangefair Lane, Anaheim, CA 92801e-mail: [email protected](714) 992-

Pagina 30 - Wiring Diagrams

January 2013L010132General DescriptionThe MBC25081 is a 2.5 amps/phase bipolar microstep driver capable of running four, six, and eight lead step moto

Pagina 31 - January 2013L010133

January 2013L010132Wiring DiagramsInput Pin DescriptionsPin # DescriptionCBL-AA4031 Wire Color1 Direction Brown2 Clock Red3 On/Off Orange4 MS2 Yellow5

Pagina 32

January 2013L010132Step Motor Confi gurationsThe output current on the MBC25081 is set by the onboard potentiometer. This potentiometer determines the

Pagina 33 - Connecting to the MBC15081

January 2013L010132Step Motor Confi gurationsStep motors can be confi gured as 4, 6 or 8 leads. Each confi guration requires different currents. Refer

Pagina 34

January 2013L010197Wiring DiagramsItem Min Typ Max UnitsInput Operating Voltage 20 48 55 VDCPhase Output Current 0.7 3.5 A (RMS)Phase Output Current 1

Pagina 35 - MBC25081

January 2013L010132Connecting to the MBC15081The MBC25081 is designed with cost savings and size as two of the primary design criteria. For this reas

Pagina 36 - MBC25081 Features

January 2013L010132ANAHEIM AUTOMATIONCOPYRIGHT Copyright 2013 by Anaheim Automation. All rights reserved. No part of this publication may be reproduce

Pagina 37

FEATURESDESCRIPTION910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comDIMENSIONS•

Pagina 38 - January 2013L010132

910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comModel # Description Input Volt

Pagina 39

FEATURESDESCRIPTION910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comDIMENSIONSI

Pagina 40

ADDITIONAL INFORMATION910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.comModel #

Pagina 41

January 2013L010197DimensionsMotor SelectionThe MBC05641 is a Bipolar Microstep Driver that is compatible with both Bipolar and Unipolar Motor Confi gu

Pagina 42 - MBC25081TB - Microstep Driver

January 2013L010197Step Motor Selection GuidePart NumberUnipolar RatingSeries Peak RatingParallel Peak RatingSeries Current SettingParallel Current Se

Pagina 43 - SINKING SOURCING

January 2013L010197Setting the Output CurrentThe output current on the MBC05641 is set by an onboard potentiometer. This potentiometer determines the

Pagina 44 - MBC12101 - Microstep Driver

January 2013L0101978 Lead MotorsSeries Connection: When confi guring the motor windings in series, use the per Phase (or unipolar) cur-rent rating to d

Pagina 45 - 34Y314S-LW8 W/MBC12101, 24V

January 2013L010197Note: After the current has been determined, according to the motor connections above, use Table 8 to choose the proper setting for